Brand Name : ESTEL

Model Number : GPE48350G

Certification : ISO9001, CE, 3C, FCC, TLC

Place of Origin : Shenzhen, China (Mainland)

MOQ : 1

Price : negotiation

Payment Terms : L/C, D/A, D/P, , T/T, Western Union

Supply Ability : 20,000 sets per month

Delivery Time : 7-10 working days

Packaging Details : carton/wooden case

Installation Mode : embedded

Output Power : 18725W

Input Voltage : AC220V

Application : mobile communication

Feature : satellite communication ground station

Input Frequency : 45~65Hz

Power Factor : 0.98

Max. Input Current : 40A

Contact Now

Telecom Rack Mount Rectifier System For Satellite Communication Ground Station

Quick Details:

Place of Origin: Shenzhen, China (Mainland) Input Voltage: AC220V
Brand Name: ESTEL Output Voltage: DC48V
Model Number: GPE48350G Output Power: 18725W
Product Name: Telecom Rectifier System Input Frequency 45~65Hz
Certification: ISO9001, CE, 3C, FCC, TLC Max. Input Current: 40A
Installation Mode: embedded Power Factor: 0.98
Application: outdoor telecom cabinet

Components:

7×50A rectifier module,

1×monitoring module,

power distribution

Payment & Shipping Terms:

Minimum Order Quantity: 1 set
Price: negotiation
Payment Terms: L/C, D/A, D/P, T/T, Western Union
Supply Ability: 20,000 sets per month
Delivery Time: 7-10 working days
Packaging Details: carton/wooden case

1. System Configuration

The system consists of power distribution unit, rectifier module (from 1 set, up to 7 sets) and 1 monitoring module. The configuration is optional, as following table:

Configuration Rectifier Module Monitoring Module Power Distribution
Standard GPR4850D GPM48P (With Ethernet Port)

AC power distribution: single phase input, AC breaker @ general line (100A/2P);

DC power distribution: battery 100A*4(fuse);

LVLD: 63A×3 32A×5 16A×4 (MCB capacity optional)

LVBD: 32A×3 16A×4(MCB capacity optional)

2. Operating Principle

AC power is first input AC-INPUT MCB and then feed into the rectifier module after lightning proof and filtering. AC-INPUT acts as protection to over load and short circuit to AC power. The user’s battery is connected to the DC output side through MCB BAT and KM2, and the circuit breaker provides disconnection control, over-load and short-circuit protection to the battery.

Under normal conditions, every parameter of rectifier modules and power distribution unit are all under control of the monitoring module, operating according to the pre-set parameter or user’s commands. If AC mains faults, the battery will power to the system. With the battery discharge, the terminal voltage of the battery starts to descend. When battery voltage is under -47V±0.5V, the monitoring module sends DC under voltage alarm signal and when battery voltage is under -46.0V±0.5V (adjustable), the KM1cuts off non-priority loads and retaining power to priority loads. If battery voltage drops to -43.0V±0.5V (adjustable), the KM2 will cut off output of priority loads and then the power system will stop working. If the external AC mains recovers, the system will normally work again. (All above monitoring data are system default values and can be reset by user).
Except for battery over-discharge protection, battery or load over-temperature protection is prohibitive under default, users can send command to activate or inactivate according to the demanding.

3. System Properties

Environment
Item Min. Typical Max. Unit Remark
Operating temperature -25 55 °C When ≥55°C, decreased power output
Storage temperature -40 80 °C
Humidity 10 90 % Relative humidity without condensing
Atmospheric pressure 70 106 KPa
Altitude 0 3000 m
Cooling Forced cooling with fan

Input
Item Min. Typical Max. Unit Remark
Input voltage range 90 220 290 Vac
Input frequency 45 50 65 Hz
Max. Input current 40 A
Power factor 0.98 Rated load
Input over voltage protection point 300 Vac Automatically recoverable
Input over voltage recovery point 290 Vac Return difference ≥5V
Input under voltage protection point 85 Vac Automatically recoverable
Input under voltage recovery point 90 Vac Return difference ≥5V
Input over current protection MCB in AC Input supply protection

Output (Table 1)
Item Min. Typical Max. Unit Remark
Output voltage 42 53.5 58 Vdc Adjustable by monitor, tested in no load
Output power 18725 W 18725W output when input voltage is 176~290VAC (rated power includes battery charging power plus load power)
9350 W 90~175VAC input
Output over voltage protection point 58.5 60.5 Vdc Lock up
Output current limiting protection point Output current limiting protection
Output short circuit protection Long-term short circuit protection, automatically recoverable
Over temperature protection Automatically recoverable in ambient temperature lower than 65°C
Battery power-down protection Battery power-down protection
Battery polarities reversal connection protection No damage on battery and power system
Voltage regulation accuracy ±1 %

Output (Table 2)
Item Min. Typical Max. Unit Remark
Temperature coefficient ±0.2 ‰/℃
Current sharing unbalance ±5 % Within 50~100% load range
Start-up/shut-down overshoot range ±5 % Any module is removed when operating, (the load current should be less than total output current of working rectifier modules), the system output voltage fluctuates
Dynamic response recovery time 200 uS

25%~50%~25% load variation

50%~75%~50% load variation

Dynamic response overshoot ±5 % Rated output voltage, rated load current
Efficiency 91 92 % 220Vac input, rated output voltage, rated load current
83 % 110Vac input, rated output voltage, rated load current
Start-up time 3 8 S pre-current limiting is fitted with start-up output between rated start up input voltage and rated output voltage established period
Pressure drop 500 mV
Peak-peak noise voltage 200 mV
Psophometrically weighted noise voltage 2 mV

Other Parameters
Item Requirement
Acoustic noise ≤55dB(A)
Smelling any abnormal and poisonous smelling is not allowed
Components rated temperature of the electrolytic capacitor ≥105℃
Hot swappable the rectifier module meets the hot-swappable requirement
Mixed insertion rectifier modules can be mixed insertion
Ineffective separation rectifier module can separate with system when it is ineffective
Cooling forced cooling by fan mounted on rectifier, face in, back out. The fan is mounted on rectifier front panel; can be disassembled. Fans include temperature control speed adjusting function.

Insulation Rating
Parameters Min. Typical Max. Unit Remark
Input-chassis 3535 Vdc
Input-output 3535 Vdc
Output-chassis 1414 Vdc
Insulating Resistance In normal atmospheric pressure, when relative humidity is 90%, testing voltage is 500VDC, the insulating resistance of input-output, input-grounding, output-grounding are all ≥10MΩ

4. Mechanical Properties

Mechanical specifications
Dimensions (Overall) as the following diagram
Weight(kg)(Overall)

≤43.5kg (Inclusive of module)

≤25kg (Frame + Distribution, exclusive of module)

Telecom Rack Mount Rectifier System For Satellite Communication Ground Station

5. Electrical Connection

Chassis connects with external electric through system interface board. As shown in figure below:

Telecom Rack Mount Rectifier System For Satellite Communication Ground Station

MCB descriptions:

1. Single-phase AC input MCB and rail type connector;

2. AC SPD;

3. LOAD (-): system load- (7 MCBs,LVBD);

4. LOAD (+): system load+ and BAT (+): battery+ (copper bar at front of system)

5. LOAD (-): system load- (12 MCBs,LVLD);

6. BAT (-): battery- (fuse)

6. Application

(1) Small scale program controlled exchangers

(2) Access network

(3) Transmission equipment

(4) Mobile communication

(5) Satellite communication ground station

(6) Microwave communication

7. Feature

(1) Adoption of active power factor compensation technology with factor >0.98

(2) Wide operating range of AC input voltage: 90~290Vac

(3) Operating temperature range: -25°C~+55°C

(4) Zero current/voltage switching tech with high efficiency ≥91%

(5) Lifecycle of battery prolonged by perfect battery management, including electrical charge/discharge management, battery temperature compensation, battery capacity test, reversal connection proof protection, low voltage protection etc.

(6) Hot-swappable

(7) Input over/under voltage protection

(8) Output over voltage protection

(9) Output over current protection

(10) Output short circuit protection

(11) Auto current sharing, parallel output

(12) Embedded mounting

8. Packing and Shipping

Telecom Rack Mount Rectifier System For Satellite Communication Ground Station

Our Delivery Agent

The goods can be shipped by sea, by air, by courier, by land, by train, etc.

Besides the following delivery agent, we can also look for the delivery agent with the best price in china if you need us to do for you.

9. Our Contact Information

Mobile Phone: 0086-13752765943

Telephone: 0086-0755 66600941

Email: info@estel.com.cn

lxf.estel@hotmail.com
Skype: fiona.liang10


Product Tags:

telecom rectifier module

      

dc rectifier system

      
China Telecom Rack Mount Rectifier System For Satellite Communication Ground Station wholesale

Telecom Rack Mount Rectifier System For Satellite Communication Ground Station Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Tianjin Estel Electronic Science and Technology Co.,Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)
 

Friendly Links: www.everychina.com

Home| Products| Suppliers| Quality Suppliers| Site Map |About Us |Contact Us |Help |关于我们 |联系我们

Copyright © 2009 - 2024 xpshou.com. All rights reserved.